Resource
Toumen Port Railway Project – Borehole Sediment Thickness Testing
Release time:
2025-09-29 10:32
Project Overview
-
Project Name: Toumen Port Railway Project
-
Project Type: Railway Foundation Engineering
-
Location: Linhai, Taizhou, Zhejiang Province, China
-
Testing Equipment: RSM-STD(C) Sediment Thickness Detector
Testing Purpose & Method
The testing was conducted as construction self-inspection to ensure the quality of borehole cleaning prior to pile concreting. Sediment thickness directly affects pile bearing capacity and long-term stability. The sediment thickness detection method was applied to verify that borehole bottom conditions met design specifications.
Testing Scope
-
Detection of sediment thickness at railway foundation pile boreholes
-
Verification of compliance with maximum allowable sediment limits
Testing Results
-
5-3# Borehole: 10 cm sediment
-
5-1# Borehole: 20 cm sediment
-
4-2# Borehole: 10 cm sediment
All results were within the 20 cm design requirement, with no abnormalities detected.
Evaluation
-
Engineering Evaluation: Borehole cleaning quality met design requirements, ensuring foundation safety and construction reliability.
-
Equipment Performance: The RSM-STD(C) provided clear and reliable measurement results, supporting accurate on-site quality control.
-
On-Site Records: Photos and videos were taken during the testing process to document the procedure and project conditions.